Standard

NEK EN 50265-2-2:1998

Tilbaketrukket

Rettelser og tillegg kjøpes separat.

Språk
Tjenester

Omfang

This standard specifies a method of testing a small insulated wire under fire conditions when the method specified in IEC Publication 332-1 is not suitable because some small conductors may melt during the application of the flame - The range of application recommended is for solid copper conductors from 0.4 mm to 0.8 mm diameter and for stranded conductors from 0.1 mm2 to 0.5 mm 2 cross-section - This standard includes the requirement for compliance - Note: The use of insulated wire which complies with this standard is not sufficient to prevent flame propagation under all conditions of installation - When the risk of propagation is high, such as with long vertical runs of bunches of wires, it cannot be assumed that, because a sample complies with this standard, the bunch will behave in a similar manner

Dokumentinformasjon

  • Standard fra NEK
  • Publisert:
  • Tilbaketrukket:
  • Utgave: 1
  • Versjon: 1
  • Varetype: NAT
  • ICS 13.220.40
  • ICS 29.060.20
  • National Committee NEK/NK20

Referanser i lov

EU lov: 73/23/EEC

Produktrelasjon