Standard

NS-EN 15096:2020

Published

Corrigendums and amendments are bought separately.

Language
Services

Abstract

This document specifies: a) the field of application; b) the requirements of hose union anti vacuum valves; c) dimensional and physio-chemical properties, and properties of general hydraulic, mechanical and acoustic design of hose union anti-vacuum valves of nominal sizes DN 15 up to and including DN 25; d) marking and technical product information. This document specifies the characteristics of hose union anti-vacuum valves of nominal size DN 15 up to and including DN 25 that are suitable for use in drinking water systems at pressures up to and including 1 MPa (10 bar) and temperatures up to and including 65 °C and for 1 h at 90 °C. HB protects against back siphonage only and is installed in vertical downward flow position. HD protects against back flow and is installed in vertical downward flow position. HB and HD anti-vacuum valves are for installation exclusively at the connecting point between stop valve and hose in vertical downward flow position.

Document information

  • Standard from SN
  • Published:
  • Edition: 2020-06
  • Version: 1
  • Document type: NAT
  • ICS 13.060.20
  • ICS 23.060.01
  • National Committee SN/K 98

Legal references

EU law: 305/2011

Product Relations

Product life cycle